OPTISWORKS-V2008 FOR SOLIDWORKS-2008 (C)OPTIS


• Simultaneously optimize optical and mechanical parts thanks to powerful optimization engine

• Import all optical systems created with traditional software

• Study tolerancing of your system thanks to multi-configuration capabilities

• Treat optical rays as 3D sketches

• Access a full set of optical components libraries

• Calculate all optical performances of your system (MTF, PSF, Spot diagrams, Aberrations…)

• Reduce system size thanks to free shape lens design & optimization
New functionalities
Virtual Human Vision Lab: Visual acuity, Condition of observation of the scene and Vision mode evaluation.

Virtual Human Vision Lab: Analysis tools.

Virtual Human Vision Lab: Legibility/Visibility tools.

ANSI/IESNA LM-63-2002 standard support.

ANSI/IESNA LM-63 Type A standard support.

Virtual Photometric Lab: Following operations on maps are now multithreaded: Open, Standard filtering, Remove highest peaks filtering, Map addition and multiplication by a value (Photometric Calc and Distributed calculation), Surface/Section calculations and Display update.

New OPTIS License Manager.

Virtual Photometric Lab: The export of spectral map to convert it into an extended map has been added.

Advanced Scattering Surface: The Autofill tool has been added to help the Advanced scattering generation.

Improvements
Availability of preferences from independent Labs: Virtual Photometric Lab, Virtual Human Vision Lab, User Material Editor, Spectrum Editor, Advanced Scattering Surface Editor and BSDF - BRDF - Anisotropic Surfaces Viewer.

IES / Eulumdat / Optis Intensity viewers: Horizontal symmetry and intensity's export to a Virtual Photometric map.

IESNA viewer: Graphic user interface for "Miscellaneous".

Sollner curve and Luminance calculation only available for IES C format.

Eulumdat viewer: Possibility to add symmetry properties on an existing intensity diagram (CAS-01655-1BEXMM).

Virtual Human Vision Lab: New Time adaptation dialog box.

Virtual Photometric Lab: Eye Illuminance.

Virtual Photometric Lab: Colorimetric data - Possibility to select a reference color and to calculate the DeltaE between the reference color and the selected color.

Rebuilt of the "Complete Scattering" model.

"Measure Treatment" feature added to the "BSDF - BRDF - Anisotropic Surfaces Viewer" to allow post-treatment of measured files.

Fixed bugs
Virtual Photometric Lab: BMP mask import has been fixed (CAS-01573-49SKT9).

Virtual Photometric Lab: The "Remove highest peaks" filtering has been corrected for radiometric values (CAS-01647-ZNBTWK).

Virtual Photometric Lab: The crash with grid parameters has been solved.

Virtual Photometric Lab: The crash when a not well written CLS file has been chosen as been solved.

Virtual Photometric Lab: The txt Import/Export command for a conoscopic map has been solved.

Virtual Photometric Lab: Saved of values for points' position of the "user line" of a conoscopic map has been solved.

Virtual Photometric Lab: The flux value when using Foot Candle has been solved (CAS-01913-AYLLNF).

When opening a Virtual Photometric Lab, the default filter with highest peaks remove has been solved.

User Material Editor: Units of the spectrum editor for fluorescence materials' absorption has been fixed (CAS-01548-DW70C2).

User Material Editor: It is not more possible to enter an index below than 1.0.

User Material Editor: A problem when displaying the index graph with very low variation of the index has been fixed.

Ray File Editor: The "Save As" command has been fixed (CAS-01929-X4J8HA).

Lambda minimum limitation for Spectrum Generation has been solved.

IESNA LM-63 Type B: The measured flux has been solved.



• Limit number of optical elements in your opto-mechanical systems